Hanna Portable Waterproof pH/EC/TDS Meter (Low Range) - HI991300
- 3 in 1 amplified probe with pH, EC/TDS and temperature sensors
- Quick Cal Mode to calibrate pH and EC/TDS with one solution
- EC to TDS Conversion factor selectable between 0.45 and 1.0
More about Hanna Portable Waterproof pH/EC/TDS Meter (Low Range) - HI991300
The HI991300 has many advanced features that are found in more expensive portable instrumentation including automatic calibration, buffer/standard recognition and temperature compensation.
The LCD screen has indicators for calibration status and stability, as well as on-screen tutorial messages. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available. The supplied HI12883 is a 3-in-1 pre-amplified multiparameter probe that measures pH, EC/TDS, and temperature within a single polypropylene body. The amplifier for the pH electrode prevents interference from humidity and sources of electrical noise include circulating pumps, motors, and ballasts for grow lights.
The design consideration for the HI991300 is ideal for measuring the pH, EC/TDS, and temperature in greenhouses, hydroponics, environmental monitoring, water treatment, wastewater treatment and boilers and cooling towers.
Simplified one button calibration
One or two point pH calibration is automatic to a pre-programmed buffer set (4.01/7.01/10.01 pH or 4.01/6.86/9.18) or single point pH and EC calibration with the Hanna Quick Cal calibration solution. To perform a quick cal calibration, simply press and hold the left power/mode button while in measurement mode for three seconds and let go to enter calibration mode. Once both pH and EC are calibrated “CAL OK” is displayed and the meter returns to measurement mode.
HI1288 polypropylene body amplified pH electrode with built-in EC/TDS and temperature sensors
The HI991300 is supplied with an amplified polypropylene body pH/EC/TDS/temperature probe. The built-in amplifier will reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include circulating pumps, motors, and ballasts for grow lights.
3 sensors in a single probe
pH electrode – Preamplified for resistance to electrical noise including that generated by pumps and ballast
EC/TDS sensor – amperometric two pole design
Temperature – NTC sensor for accurate temperature measurement and compensation
Waterproof
Designed to withstand the humidity of a growing environment
Wide pH Range
pH range is from 0.00 to 14.00 pH
Selectable EC to TDS conversion factor
Choice of either a 0.5 or 0.7 conversion factor
0.5 (500 CF) conversion factor is for an EC reading of 1000 μS/cm = 500 ppm
0.7 (700 CF) conversion factor is for an EC reading of 1000 μS/cm = 700 ppm
Automatic Temperature Compensation
All readings are compensated for variations in temperature
Temperature displayed in oC or oF along with pH, EC or TDS reading.
Stability indicator
Meter displays a clock tag that will disappear when the reading has achieved stability
HOLD button
Freezes reading on the display to allow recording of measurement
BEPS (Battery Error Prevention System
Meter will automatically shut off if there is not enough power to get an accurate measurement
Battery % level at startup
Low Battery Indicator
When the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.
Auto-off
User selectable automatic shut-off ff to conserve battery life. Options are after 8 minutes, 60 minutes , or disabled.
SKU | 06028000073 |
---|---|
Part Number | HI991300 |
Acomba | HI991300 |
Shipping Weight (lbs) | N/A |
Shipping Length (in) | N/A |
Shipping Width (in) | N/A |
Shipping Height (in) | N/A |
USD Price | 750.30 |
Quantity per case | 0.000000 |
Quantity per pallet | 0.000000 |